Methanometer

Objective:

  • Capable of measuring the concentration of Methane / LPG gas
  • Low power signal conditioning unit and robust packaging for different applications

                                                                                                               

Features:

  • User friendly & easy to operate
  • Portable (70mm X 135mm X 30mm )
  • Low power consumption (60mW for signal conditioning unit )
  • Fast response time (15 Sec)
  • Onboard microcontroller programming facility
  • Extended probe to find out the leak in a narrow area
  • A small FAN to remove the residual gas
  • 16 X 2 LCD screen to Display the gas concentration present in hazardous area
  • Three levels of LED indication (Green, Yellow &Red ) with buzzer depending on the concentration of gas (safe, moderate, and danger)
  • Two pencil battery (1.5V X 2)

Sensors used

  • MP-4 flat-surfaced sensor made by WINSEN Electronics Technology, China
  • High Selectivity to Methane
  • Broad detection range (300 to 10000 PPM)
  • Power consumption 300mW

Hardware

  • ATMEGA 8 µcontroller
  • DC-DC Boost Converter

Software

  • BASCOM
  • PROTEUS